Skip to main content

Technical Specifications

Security Grade

SpecificationDetails
StandardPD 6662:2010, EN 50131-1:2006+A1:2009 (Grade 2) & EN 50131-6:2008 (Grade 2)

Temperature / Humidity

SpecificationDetails
Operating Range-10°C to +40°C / 75% non-condensing (Class II)

Power Supply (Type A)

SpecificationDetails
Mains Input150mA (max.), 230Vac +10%/-10%, 50Hz
DC Output10Vdc to 13.9Vdc. SMPS rated to deliver 1.5A max.
Auxiliary power output125mA (limited by a 750mA fuse)
RKP bus power output125mA (limited by a 750mA fuse)
Rippleat 250mA = 25mV peak to peak (max.)

Battery

SpecificationDetails
Battery12.0V, 7,200mAh, Lead Acid (max.) To be supplied by installer
Max. recharge time24h (floating charge = 13.65Vdc ±1.5%)
Low battery detection voltage10V

Physical

SpecificationDetails
Product Weight1,430g
Size360mm x 236mm x 90mm
Housing MaterialPolycarbonate/ABS

Mains Fuse

SpecificationDetails
Mains Fuse3.15A (T) High Breaking Capacity 20x5mm

Logical Keys

SpecificationDetails
Number of variations472,391 - i.e. with 6 digits ((9x9x9x9x9x8)-1)
note

0 is disallowed in all digits & 9 is disallowed in the last digit only.

Outputs

STROBE, INT BELL & EXT BELL outputs limited with 300mA fuses.

Current Consumption

DeviceQuiescentActive / Peak
Panel75mA-
Keypad30mA60-120mA (light & sound)
Expander80mA160mA (relays on)
Dialler80mA115mA (relay on)
SABB40mA360mA (peak) alarm
ID Sensor2mA5mA alarm
PIR9.5mA8.5mA alarm
GSM-Q20mA140mA transmit
GSM-WiFi30mA70mA max.
Output card2mA190mA (relays on)
Ethernet30mA-
RF-Expander65mA150mA max.

Max. Number per System

DeviceMax.DeviceMax.
Wired RKP8Zone Expander13
Point ID Sensors40RF-Keypad2
SABB2RF-SABB10
RF-ECHO10GSM-Q/WiFi1
PSU (ID bus)20Output Card20
RF-Expanders15
RF Devices (total)200RF-Keyfob64

Cabling (standard alarm cable)

RouteMax. Distance
Panel to SABB50m
Panel to remote device on RKP bus150m
Total cable on RKP bus500m
Panel to remote device on Point ID bus200m
Total cable on Point ID bus600m

Zone

Zone has Inertia Sensor analysis. Zone is configurable for non-EOL, single-EOL and dual-EOL resistance. EOL resistor = 4k7Ω or 2k2Ω. Response = 300ms.

Auto-inhibit

By default, multiple activations on a zone will re-trigger the siren(s) a maximum of 3 times and be logged a maximum of 10 times.