Users / Codes

UserCodeOptions
Engineer04567Engineer Mode
User 101111Full Set, Unset, Inhibit, Partset A, Partset B
User 2-64NoneFull Set, Unset, Inhibit, Partset A, Partset B

Options

Arming Options

OptionEnabled
Final DoorNo
Exit Fault BellYes
Line Fault BellNo
Inhibit TamperNo
Forced ArmYes
Displayed ArmedNo
Extn'ed Block ExitNo
Rearm AlwaysNo
Rearm Count3

Buzzer Options

OptionEnabled
Mains Fault BuzzerYes
Line Fault BuzzerYes
FTC BuzzerYes

Comms. Options

OptionEnabled
Remote AccessYes
Secure AccessNo
Local AccessYes
Printer PortNo

Keypad PA Options

OptionEnabled
Keypad * & # PANo
Keypad PA SilentYes
Silent PA; Line FaultYes

Printer Options

OptionEnabled
Real Time LogNo
Use Form FeedNo

Unset Options

OptionEnabled
User Walk TestYes
Fire Output EnabledYes
Extn'ed Block EntryNo
Fire Exit BellsNo
Fire Exit Req. CodeYes

Misc. Options

OptionEnabled
Timed SoakNo
Engineer LockNo
Duress CodesNo
Walk Test BellYes
System Double KnockNo
Latch ChimeNo
Internal Bell ChimeNo
Auto Hour ChangeYes
Work to EN50131Yes

Part Set Options

OptionEnabled
Part Set A Exit TimeNo
Part Set B Exit TimeNo
Access to Entry/ExitNo
Part Set Digi AlarmYes
Indicate Part SetNo
Part Set A Exit BuzzerNo
Part Set B Exit BuzzerNo

Quick Key Options

Quick KeyEnabled
0#1 - User LogNo
0#3 - Walk TestNo
0#4 - Full ArmNo
0#5 - Quick ArmNo
0#6 - Toggle ChimeNo
0#7 - Part Set ANo
0#8 - Part Set BNo
0#9 - Bell TestNo
0*1 - SMS EngineersYes
0*2 - SMS LogYes
0*3 - Call PCYes
0*4 - PC DirectYes
0*5 - User CheckYes
0*6 - Temporary UserYes
0*7 - Home AloneYes

Garda Policy

OptionEnabled
Pre-AlarmYes
Bell Tamp = VerfiedYes
Alarm Abort Time00 Min

RF-Contact/Sensor

OptionEnabled
Reeds EnabledYes

Timers

TimerUnitValue
Internal BellMinutes15
External BellMinutes15
Entry TimeSeconds30
Exit TimeSeconds30
Split Entry TimeSeconds30
Soak PeriodDays00 Infinite
Bell DelayMinutes00
Double Knock ResetMinutes05
Double Knock OpenSeconds10

Misc. Timers

TimerUnitValue
Weeks to ServiceWeeks00 Infinite
Fire Exit DelayMinutes00
Mains Fault DelayMinutes55

Zone Defaults

Zone No.Zone TypeZone Options
Zone 1Entry/ExitInhibit, Chime
Other zonesAlarmInhibit

Point Defaults

Point No.Zone TypeZone OptionsGrossPulse
Point 01 to 10AlarmInhibit44

In the UK...

Users / Codes

UserCodeOptions
Engineer04567Engineer Mode
User 101234Full Set, Unset, Inhibit, Partset A, Partset B
User 2-64NoneFull Set, Unset, Inhibit, Partset A, Partset B

Arming Options

OptionEnabled
Final DoorYes
Exit Fault BellYes
Line Fault BellNo
Inhibit TamperNo
Forced ArmYes
Displayed ArmedNo
Extn'ed Block ExitNo
Rearm AlwaysNo
Rearm Count3

Misc. Options

OptionEnabled
Timed SoakNo
Engineer LockNo
Duress CodesNo
Walk Test BellYes
System Double KnockNo
Latch ChimeYes
Internal Bell ChimeNo
Auto Hour ChangeYes
Work to EN50131Yes

Part Set Options

OptionEnabled
Part Set A Exit TimeNo
Part Set B Exit TimeNo
Access to Entry/ExitYes
Part Set Digi AlarmNo
Indicate Part SetNo
Part Set A Exit BuzzerNo
Part Set B Exit BuzzerNo

Timers

TimerValue
Internal Bell15m
External Bell15m
Entry Time30s
Exit Time30s
Split Entry Time00s
Soak Period00d
Bell Delay00m
Double Knock Reset05m
Double Knock Open10s

BS8243 Options

OptionEnabled
Alarm ConfirmYes
Alarm Confirm Time30m
Panic ConfirmYes
Panic Confirm Time8h
Auto InhibitYes
Prox EntryYes
Access / BVNo
Engineer ResetYes
Restricted IndicationYes

Technistore

OptionEnabled
EnabledNo

Digi Defaults

Universally...

AVI Settings

SettingDefault
AVI Time30 Seconds
AVI MessageCALL MONITORING.
AVI AudioNo

Channel

ChannelTypeTriggerRestoreDelay
1FirePositiveYes0 secs.
2PanicPositiveYes0 secs.
3AlarmPositiveYes20 secs.
7Pre-alarmPositiveYes20 secs.

Options

OptionDefault
Dual ReportNo
5 Second IntervalNo
Max. Attempts12
FTC Attempts03
Retry Period60m
Using PABXNo
SMS Attempts12
Max SMS Messages07
SMS Alarm Delay00s
Voice Attempts03
Max Voice Messages02
Voice Message Delay00s
note

In Phone Report Menu, only Fire, Panic, Alarm, Pre-alarm, Test Call & Low Battery are defaulted to report to Central Station phones 1 & 2. All other events need to be assigned to phones by the installer.

Line Monitor Options

OptionDefault
Line Monitor OnYes
Off-Hook Monitor OnNo
Off-Hook/Line Fault (Unset)No

Misc. Options

OptionDefault
Text EnableYes
SmartLink700 ProgressYes

Modem Options

OptionDefault
Use Caller IDNo
Line ShareNo
Rings Before AnswerNo

Monitoring/Voice Ph. Nos.

PhoneMonitoring/Voice Ph. Nos.Account No.Site NameProtocol
1Not ProgrammedNot ProgrammedExtended SIA
2Not ProgrammedNot ProgrammedExtended SIA
3Not ProgrammedNot RecordedVoice
4Not ProgrammedNot RecordedVoice

Phone Wait for Dial Tone

PhoneWait for Dial Tone
1 to 4Yes
SMSYes
SmartLink700Yes

SMS Server Phone No's

ServerNumber
Server #1014297100
Server #2

SMS Phone

SMS PhoneAlarmSystemArmSoakFire ExitDevice
1 to 7YesNoNoNoNoNo

Test Call Settings

SettingDefault
Test Starthh:mm
Test Period0 Hours

GSM/GPRS

OptionDefault
Monitor SignalYes
Fault Delay05m
Jam DetectYes
Answer CallsNo
Use Caller IDNo
Enable GPRSNo

IP Settings

OptionDefault
DHCP EnabledYes
SCPCP Server EnabledNo
SCPCP Server EncryptionNo

In the UK...

Channel

ChannelTypeTriggerRestoreDelay
1FirePositiveYes0 secs.
2PanicPositiveYes0 secs.
3Intruder AlrmPositiveYes30 secs.
4Open/ClosePositiveYes0 secs.
5Zone OmitPositiveYes0 secs.
6Mains FailPositiveYes*0 secs.
7Confirm AlrmPositiveYes30 secs.

*0 second channel delay after 55 minutes of no mains